Review



illumination lasers  (Coherent Corp)


Bioz Verified Symbol Coherent Corp is a verified supplier
Bioz Manufacturer Symbol Coherent Corp manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 98

    Structured Review

    Coherent Corp illumination lasers
    Illumination Lasers, supplied by Coherent Corp, used in various techniques. Bioz Stars score: 98/100, based on 3030 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/obis+laser+illumination+system/OBIS/pmc13035910-465-20-27
    Average 98 stars, based on 3030 article reviews
    illumination lasers - by Bioz Stars, 2026-10
    98/100 stars

    Images

    Related Articles

    Microscopy:

    Article Title: N-Cadherin/α-Catenin Drive Adhesion and Actin Regulation to Orchestrate Tunneling Nanotube Formation
    Article Snippet: Finally, samples were mounted on glass slides with Aqua PolyMount (Polysciences, Inc.). .. Various Z-stacks images of different random points of the samples are acquired with either an inverted laser scanning confocal microscope LSM700 (Zeiss) controlled by the Zen software (Zeiss); or by a spinning disk Eclipse Ti2 inverted microscope (Nikon) equipped with a CSU- W1 spinning disk confocal scanning unit (Yokogawa), a 60× 1.4 NA oil immersion objective (Nikon Plan Apo VC), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), and a Prime 95B sCMOS camera (Teledyne Photometrics). .. Acquisition was controlled by Nikon’s NIS-Elements software.

    Software:

    Article Title: N-Cadherin/α-Catenin Drive Adhesion and Actin Regulation to Orchestrate Tunneling Nanotube Formation
    Article Snippet: Finally, samples were mounted on glass slides with Aqua PolyMount (Polysciences, Inc.). .. Various Z-stacks images of different random points of the samples are acquired with either an inverted laser scanning confocal microscope LSM700 (Zeiss) controlled by the Zen software (Zeiss); or by a spinning disk Eclipse Ti2 inverted microscope (Nikon) equipped with a CSU- W1 spinning disk confocal scanning unit (Yokogawa), a 60× 1.4 NA oil immersion objective (Nikon Plan Apo VC), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), and a Prime 95B sCMOS camera (Teledyne Photometrics). .. Acquisition was controlled by Nikon’s NIS-Elements software.

    Inverted Microscopy:

    Article Title: N-Cadherin/α-Catenin Drive Adhesion and Actin Regulation to Orchestrate Tunneling Nanotube Formation
    Article Snippet: Finally, samples were mounted on glass slides with Aqua PolyMount (Polysciences, Inc.). .. Various Z-stacks images of different random points of the samples are acquired with either an inverted laser scanning confocal microscope LSM700 (Zeiss) controlled by the Zen software (Zeiss); or by a spinning disk Eclipse Ti2 inverted microscope (Nikon) equipped with a CSU- W1 spinning disk confocal scanning unit (Yokogawa), a 60× 1.4 NA oil immersion objective (Nikon Plan Apo VC), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), and a Prime 95B sCMOS camera (Teledyne Photometrics). .. Acquisition was controlled by Nikon’s NIS-Elements software.

    Article Title: Tunnelling nanotube formation is driven by Eps8/IRSp53-dependent linear actin polymerization.
    Article Snippet: .. Tracking cell confinement on micropatterns Brightfield and fluorescence imaging was performed on an inverted Eclipse Ti-E or Ti2 inverted microscope (Nikon) equipped with either a CSU-X1 or a CSU-W1 spinning disk confocal scanning unit (Yokogawa), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), a 40× 1.15 NA objective (CFI Apochromat LWD Lambda S, Nikon), and a Prime 95B sCMOS camera (Teledyne Photometrics). .. CAD cells were first preadhered for 1 h to the micropatterns and then imaged every 5 min over 18 h using MetaMorph or NIS-Elements (Nikon) for instrumental control.

    Article Title: Tunnelling nanotube formation is driven by Eps8/IRSp53‐dependent linear actin polymerization
    Article Snippet: One hour prior to the start of acquisition, samples were mounted on a Chemlide CMB 35 mm magnetic chamber (Quorum Technologies) and treated with 50 μM CK-666 or an equivalent amount of DMSO solubilized in phenol-free complete Opti-MEM medium containing ProLongTM Live Antifade Reagent (Invitrogen) at a 1:75 dilution. .. Time-lapse imaging of an existing TNT connecting well-patterned CAD cells was performed on an Eclipse Ti2 inverted microscope (Nikon) equipped with a CSU-W1 spinning disk confocal scanning unit (Yokogawa), a 60× 1.4 NA oil immersion objective (Nikon Plan Apo VC), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), and a Prime 95B sCMOS camera (Teledyne Photometrics). .. Acquisition was controlled by Nikon’s NIS-Elements software, and a humidified 37°C and a 5% CO2 environment was maintained in an OkoLab enclosure.

    Article Title: Arp2/3 inhibition switches Eps8’s network associations to favour longer actin filament formation necessary for tunneling nanotubes
    Article Snippet: Samples were mounted on a Chemlide CMB 35 mm magnetic chamber (Quorum Technologies). .. Time-lapse imaging was performed on an Eclipse Ti-E inverted microscope (Nikon) equipped with a CSU-X1 spinning disk confocal scanning unit (Yokogawa), a 60X 1.4 NA oil immersion objective (Nikon Plan Apo VC), a fiber-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), and Prime 95B sCMOS cameras (Teledyne Photometrics) for single or dual camera mode acquisition. .. Acqusition was controlled by MetaMorph.

    Article Title: Tunnelling nanotube formation is driven by Eps8/IRSp53-dependent linear actin polymerization.
    Article Snippet: One hour prior to the start of acquisition, samples were mounted on a Chemlide CMB 35 mm magnetic chamber (Quorum Technologies) and treated with 50 μM CK-666 or an equivalent amount of DMSO solubilized in phenol-free complete Opti-MEM medium containing ProLongTM Live Antifade Reagent (Invitrogen) at a 1:75 dilution. .. Time-lapse imaging of an existing TNT connecting well-patterned CAD cells was performed on an Eclipse Ti2 inverted microscope (Nikon) equipped with a CSU-W1 spinning disk confocal scanning unit (Yokogawa), a 60× 1.4 NA oil immersion objective (Nikon Plan Apo VC), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), and a Prime 95B sCMOS camera (Teledyne Photometrics). .. Acquisition was controlled by Nikon’s NIS-Elements software, and a humidified 37°C and a 5% CO2 environment was maintained in an OkoLab enclosure.

    Article Title: Tunnelling nanotube formation is driven by Eps8/IRSp53‐dependent linear actin polymerization
    Article Snippet: .. Tracking cell confinement on micropatterns Brightfield and fluorescence imaging was performed on an inverted Eclipse Ti-E or Ti2 inverted microscope (Nikon) equipped with either a CSU-X1 or a CSU-W1 spinning disk confocal scanning unit (Yokogawa), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), a 40× 1.15 NA objective (CFI Apochromat LWD Lambda S, Nikon), and a Prime 95B sCMOS camera (Teledyne Photometrics). .. CAD cells were first preadhered for 1 h to the micropatterns and then imaged every 5 min over 18 h using MetaMorph or NIS-Elements (Nikon) for instrumental control.

    Article Title: Arp2/3 inhibition switches Eps8’s network associations to favour longer actin filament formation necessary for tunneling nanotubes
    Article Snippet: .. Brightfield and fluorescence imaging was performed on an inverted Eclipse Ti-E or Ti2 inverted microscope (Nikon) equipped with either a CSU-X1 or a CSU-W1 spinning disk confocal scanning unit (Yokogawa), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), a 40X 1.15 NA objective (CFI Apochromat LWD Lambda S, Nikon), and a Prime 95B sCMOS camera (Teledyne Photometrics). .. CAD cells were first pre-adhered for 1 hr to the micropatterns and then imaged every 5 min over 18 hr using MetaMorph or NIS-Elements (Nikon) for instrumental control.

    Fluorescence:

    Article Title: Tunnelling nanotube formation is driven by Eps8/IRSp53-dependent linear actin polymerization.
    Article Snippet: .. Tracking cell confinement on micropatterns Brightfield and fluorescence imaging was performed on an inverted Eclipse Ti-E or Ti2 inverted microscope (Nikon) equipped with either a CSU-X1 or a CSU-W1 spinning disk confocal scanning unit (Yokogawa), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), a 40× 1.15 NA objective (CFI Apochromat LWD Lambda S, Nikon), and a Prime 95B sCMOS camera (Teledyne Photometrics). .. CAD cells were first preadhered for 1 h to the micropatterns and then imaged every 5 min over 18 h using MetaMorph or NIS-Elements (Nikon) for instrumental control.

    Article Title: Tunnelling nanotube formation is driven by Eps8/IRSp53‐dependent linear actin polymerization
    Article Snippet: .. Tracking cell confinement on micropatterns Brightfield and fluorescence imaging was performed on an inverted Eclipse Ti-E or Ti2 inverted microscope (Nikon) equipped with either a CSU-X1 or a CSU-W1 spinning disk confocal scanning unit (Yokogawa), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), a 40× 1.15 NA objective (CFI Apochromat LWD Lambda S, Nikon), and a Prime 95B sCMOS camera (Teledyne Photometrics). .. CAD cells were first preadhered for 1 h to the micropatterns and then imaged every 5 min over 18 h using MetaMorph or NIS-Elements (Nikon) for instrumental control.

    Article Title: Arp2/3 inhibition switches Eps8’s network associations to favour longer actin filament formation necessary for tunneling nanotubes
    Article Snippet: .. Brightfield and fluorescence imaging was performed on an inverted Eclipse Ti-E or Ti2 inverted microscope (Nikon) equipped with either a CSU-X1 or a CSU-W1 spinning disk confocal scanning unit (Yokogawa), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), a 40X 1.15 NA objective (CFI Apochromat LWD Lambda S, Nikon), and a Prime 95B sCMOS camera (Teledyne Photometrics). .. CAD cells were first pre-adhered for 1 hr to the micropatterns and then imaged every 5 min over 18 hr using MetaMorph or NIS-Elements (Nikon) for instrumental control.

    Imaging:

    Article Title: Tunnelling nanotube formation is driven by Eps8/IRSp53-dependent linear actin polymerization.
    Article Snippet: .. Tracking cell confinement on micropatterns Brightfield and fluorescence imaging was performed on an inverted Eclipse Ti-E or Ti2 inverted microscope (Nikon) equipped with either a CSU-X1 or a CSU-W1 spinning disk confocal scanning unit (Yokogawa), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), a 40× 1.15 NA objective (CFI Apochromat LWD Lambda S, Nikon), and a Prime 95B sCMOS camera (Teledyne Photometrics). .. CAD cells were first preadhered for 1 h to the micropatterns and then imaged every 5 min over 18 h using MetaMorph or NIS-Elements (Nikon) for instrumental control.

    Article Title: Tunnelling nanotube formation is driven by Eps8/IRSp53‐dependent linear actin polymerization
    Article Snippet: One hour prior to the start of acquisition, samples were mounted on a Chemlide CMB 35 mm magnetic chamber (Quorum Technologies) and treated with 50 μM CK-666 or an equivalent amount of DMSO solubilized in phenol-free complete Opti-MEM medium containing ProLongTM Live Antifade Reagent (Invitrogen) at a 1:75 dilution. .. Time-lapse imaging of an existing TNT connecting well-patterned CAD cells was performed on an Eclipse Ti2 inverted microscope (Nikon) equipped with a CSU-W1 spinning disk confocal scanning unit (Yokogawa), a 60× 1.4 NA oil immersion objective (Nikon Plan Apo VC), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), and a Prime 95B sCMOS camera (Teledyne Photometrics). .. Acquisition was controlled by Nikon’s NIS-Elements software, and a humidified 37°C and a 5% CO2 environment was maintained in an OkoLab enclosure.

    Article Title: Arp2/3 inhibition switches Eps8’s network associations to favour longer actin filament formation necessary for tunneling nanotubes
    Article Snippet: Samples were mounted on a Chemlide CMB 35 mm magnetic chamber (Quorum Technologies). .. Time-lapse imaging was performed on an Eclipse Ti-E inverted microscope (Nikon) equipped with a CSU-X1 spinning disk confocal scanning unit (Yokogawa), a 60X 1.4 NA oil immersion objective (Nikon Plan Apo VC), a fiber-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), and Prime 95B sCMOS cameras (Teledyne Photometrics) for single or dual camera mode acquisition. .. Acqusition was controlled by MetaMorph.

    Article Title: Tunnelling nanotube formation is driven by Eps8/IRSp53-dependent linear actin polymerization.
    Article Snippet: One hour prior to the start of acquisition, samples were mounted on a Chemlide CMB 35 mm magnetic chamber (Quorum Technologies) and treated with 50 μM CK-666 or an equivalent amount of DMSO solubilized in phenol-free complete Opti-MEM medium containing ProLongTM Live Antifade Reagent (Invitrogen) at a 1:75 dilution. .. Time-lapse imaging of an existing TNT connecting well-patterned CAD cells was performed on an Eclipse Ti2 inverted microscope (Nikon) equipped with a CSU-W1 spinning disk confocal scanning unit (Yokogawa), a 60× 1.4 NA oil immersion objective (Nikon Plan Apo VC), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), and a Prime 95B sCMOS camera (Teledyne Photometrics). .. Acquisition was controlled by Nikon’s NIS-Elements software, and a humidified 37°C and a 5% CO2 environment was maintained in an OkoLab enclosure.

    Article Title: Tunnelling nanotube formation is driven by Eps8/IRSp53‐dependent linear actin polymerization
    Article Snippet: .. Tracking cell confinement on micropatterns Brightfield and fluorescence imaging was performed on an inverted Eclipse Ti-E or Ti2 inverted microscope (Nikon) equipped with either a CSU-X1 or a CSU-W1 spinning disk confocal scanning unit (Yokogawa), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), a 40× 1.15 NA objective (CFI Apochromat LWD Lambda S, Nikon), and a Prime 95B sCMOS camera (Teledyne Photometrics). .. CAD cells were first preadhered for 1 h to the micropatterns and then imaged every 5 min over 18 h using MetaMorph or NIS-Elements (Nikon) for instrumental control.

    Article Title: Arp2/3 inhibition switches Eps8’s network associations to favour longer actin filament formation necessary for tunneling nanotubes
    Article Snippet: .. Brightfield and fluorescence imaging was performed on an inverted Eclipse Ti-E or Ti2 inverted microscope (Nikon) equipped with either a CSU-X1 or a CSU-W1 spinning disk confocal scanning unit (Yokogawa), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), a 40X 1.15 NA objective (CFI Apochromat LWD Lambda S, Nikon), and a Prime 95B sCMOS camera (Teledyne Photometrics). .. CAD cells were first pre-adhered for 1 hr to the micropatterns and then imaged every 5 min over 18 hr using MetaMorph or NIS-Elements (Nikon) for instrumental control.

    other:

    Article Title: Tunnelling nanotube formation is driven by Eps8/IRSp53‐dependent linear actin polymerization
    Article Snippet: Time-lapse imaging of an existing TNT connecting well-patterned CAD cells was performed on an Eclipse Ti2 inverted microscope (Nikon) equipped with a CSU-W1 spinning disk confocal scanning unit (Yokogawa), a 60X 1.4 NA oil immersion objective (Nikon Plan Apo VC), a fibre-coupled Coherent OBIS laser illumination system (405/488/561/640 nm), and a Prime 95B sCMOS camera (Teledyne Photometrics).



    Similar Products

    98
    Coherent Corp illumination lasers
    Illumination Lasers, supplied by Coherent Corp, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/obis+laser+illumination+system/OBIS/pmc13035910-465-20-27
    Average 98 stars, based on 1 article reviews
    illumination lasers - by Bioz Stars, 2026-10
    98/100 stars
      Buy from Supplier

    98
    Coherent Corp obis laser illumination system
    Obis Laser Illumination System, supplied by Coherent Corp, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/obis+laser+illumination+system/OBIS/bio_rxiv__2025__06__27__661900-242-63-62
    Average 98 stars, based on 1 article reviews
    obis laser illumination system - by Bioz Stars, 2026-10
    98/100 stars
      Buy from Supplier

    86
    Teledyne Photometrics obis laser illumination system
    Obis Laser Illumination System, supplied by Teledyne Photometrics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/obis+laser+illumination+system/illumination+laser+obis+system/bio_rxiv__2025__06__27__661900-242-63-75
    Average 86 stars, based on 1 article reviews
    obis laser illumination system - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    Image Search Results